LEIHONG / STANDARD PANEL DIMENSIONS

FRP Grating Standard Sizes & Dimensions Specification Guide

Compare standard molded grating panel sizes, mesh geometry, depth and weight before ordering. Leihong’s catalog includes 1226 × 3666mm, 1007 × 3007mm and other configuration-specific panels, with cut-to-drawing fabrication inquiries welcomed.

Depth: 25 / 30 / 38 / 50mm & moreSquare / mini mesh / rectangularMetric & imperial conversionStock availability on request

1226 × 3666mm ≈ 48.27 × 144.33in · 38mm ≈ 1.496in
Hebei Leihong FRP Technology Co., Ltd. · Factory-direct panel inquiries

HABH = panel depth · A / B = mesh pitchTapered bars: top width ≠ bottom width
Geometry concept only, not a dimensional manufacturing drawing. Mesh pitch is center-to-center; clear opening is smaller.

01 / Catalog specification matrix

Standard Molded FRP Grating Size & Specification Chart

The following 25 catalog configurations are transcribed from PDF page 4. Select units and filter the depth or mesh family. Confirm the exact variant, tolerances and current availability when ordering.

FamilyDepthMesh pitch A × BBar top / bottomCatalog panel sizesOpen areaTheoretical weight
Square13 mm38.1 × 38.1 mm5.8 / 5 mm1226 × 3666 mm78%6 kg/m²
Square13 mm50.8 × 50.8 mm5.8 / 5 mm1226 × 3666 mm82%5.8 kg/m²
Square25 mm38.1 × 38.1 mm6.4 / 5 mm1226 × 3666 mm68%12.3 kg/m²
Square25 mm40 × 40 mm6.4 / 5 mm1007 × 3007 mm67%12 kg/m²
Square25 mm50.8 × 50.8 mm7.5 / 6 mm1226 × 3666 mm80%11.7 kg/m²
Square30 mm38.1 × 38.1 mm6.5 / 5 mm1226 × 3666 mm68%14.6 kg/m²
Square30 mm40 × 40 mm6.5 / 5 mm1007 × 3007 mm67%14.2 kg/m²
Square38 mm38.1 × 38.1 mm7 / 5 mm1226 × 3666 mm; 1530 × 3969 mm68%19.5 kg/m²
Square40 mm40 × 40 mm7 / 5 mm1007 × 3007 mm; 1007 × 4007 mm67%19 kg/m²
Square40 mm83 × 83 mm7 / 5 mm1007 × 3007 mm84%9.5 kg/m²
Square50 mm50.8 × 50.8 mm8 / 5 mm1226 × 3666 mm; 1226 × 3055 mm78%23.5 kg/m²
Square60 mm38.1 × 38.1 mm11.5 / 9 mm1220 × 3660 mm54%50.4 kg/m²
Square60 mm60 × 60 mm10 / 6 mm1510 × 2410 mm68%25 kg/m²
Mini mesh15 mm20 × 20 mm8 / 6 mm1007 × 3007 mm42%10.5 kg/m²
Mini mesh25 mm19 × 19 mm6.5 / 5 mm1226 × 3666 mm40%16.8 kg/m²
Mini mesh30 mm20 × 20 mm6.5 / 5 mm1007 × 3007 mm42%18 kg/m²
Mini mesh38 mm19 × 19 mm7 / 5 mm1524 × 4000 mm40%23.5 kg/m²
Mini mesh40 mm20 × 20 mm7 / 5 mm1007 × 4047 mm42%23.7 kg/m²
Mini mesh50 mm25 × 25 mm8 / 6 mm1524 × 4000 mm55%28.5 kg/m²
Rectangular25 mm25.4 × 101.6 mm6.5 / 5 mm1220 × 3660 mm67%13.8 kg/m²
Rectangular30 mm25 × 100 mm7 / 5.5 mm1007 × 3007 mm67%15.6 kg/m²
Rectangular38 mm25.4 × 101.6 mm8 / 6 mm1220 × 3660 mm62%22.5 kg/m²
Rectangular38 mm25.4 × 152.4 mm8.5 / 6 mm1220 × 3660 mm63%22.5 kg/m²
Rectangular38 mm38.1 × 152.4 mm7 / 5 mm1220 × 3660 mm67%16 kg/m²
Rectangular40 mm60 × 220 mm6.3 / 5 mm1788 × 2238 mm67%8.8 kg/m²

Source: Leihong FRP gratings and pultruded parts catalogue-LH, PDF page 4. Panel dimensions are reproduced as listed. Other pages may describe different tooling variants. Imperial values are calculated equivalents, not substituted nominal sizes.

Pitch, open area and clear aperture are different measurements.

Open area affects light, air and water entry, but does not establish hydraulic flow capacity or heel-safe performance. Confirm actual clear openings and applicable route requirements. Bar taper and geometry affect the opening at the walking face.

Request a Special Mesh or Depth Review →
Request Product Drawings & Tolerances

02 / Panel sizes & cutting yield

Standard Panel Dimensions & Material Yield Optimization

4 × 12ft: nominal versus actual

Exactly 4 × 12ft equals 1219.2 × 3657.6mm. The catalog lists 1226 × 3666mm for several molded variants and 1220 × 3660mm for some others. Order by the actual selected size.

1m × 3m is not 3 × 10ft

Exactly 3 × 10ft equals 914.4 × 3048mm. A 1007 × 3007mm panel is a different footprint, even if both suit narrow routes.

4 × 8ft inquiry option

Exactly 4 × 8ft equals 1219.2 × 2438.4mm. A requested 1220 × 2440mm format is not listed in the transcribed page-4 table; confirm manufacturing or cutting feasibility.

Check support direction before optimizing cuts.

Panel orientation, edge bars, openings and cutouts affect the structural arrangement. Pultruded bearing bars require a defined span direction. A high area yield alone is not an approved panel layout.

Simple Rectangular Cutting Estimate

Millimeters only. Estimates identical rectangular pieces in a grid, with an optional 90° orientation comparison.

Enter dimensions and calculate.

Grid estimate only. Excludes trim allowance, mesh position, edge-bar requirements, mixed nesting, supports and cutouts. Rotation needs structural approval. No guaranteed waste below 5% is assumed.

Request Drawing-Based Cutting Layout →

03 / Depth selection

How to Choose the Right Standard Grating Depth

Depth is one input. Select using the exact mesh, span, load case, support conditions, temperature and deflection requirement.

25 mm

Calculated: 0.984 in

25mm Grating

Evaluate for suitable light-access or drainage layouts with verified support and load data.

View Load & Deflection Guide →
38 mm

Calculated: 1.496 in

38mm Grating

A common industrial inquiry depth; the catalog lists square, mini-mesh and rectangular variants with different weights.

View Load & Deflection Guide →
50 mm

Calculated: 1.969 in

50mm Grating

Evaluate for more demanding layouts using exact product data. Depth alone does not approve carts, forklifts or a vehicle crossing.

View Load & Deflection Guide →

30mm is approximately 1.181in, not exactly 1.25in. A specified 1¼in depth equals 31.75mm. Confirm the actual metric or imperial product requirement.

04 / Resin & surface options

Material & Surface Finishes Available in Standard Sizes

Orthophthalic

Discuss for suitable general service based on actual exposure.

Isophthalic

Evaluate for selected industrial or wastewater conditions.

Vinyl ester

Evaluate demanding chemical service with formulation-specific compatibility data.

Color does not identify resin type. Confirm the resin formulation, color and any fire or chemical evidence in the order specification.

Walking Surface & Cover Construction

Concave / meniscus

A molded top profile for foot contact; inspect wear and confirm wet traction.

Gritted top

Abrasive particles bonded into the surface. Specify grit, bonding and required slip-test conditions.

Smooth or covered panels

Review finish, total depth and support. A covered top changes drainage; odor or liquid sealing requires engineered joints and seals.

05 / Factory fabrication

Custom Fabrication & Cutting from Standard Panels

Send dimensioned drawings for panel marks, openings, support edges and proposed orientation. Confirm the fabrication method, tolerances and delivery plan with the quote.

01

Plan & Cut

Review angled cuts, circular clearances and pipe or post openings. Add supports where the load path is interrupted.

02

Finish & Seal

Agree edge preparation, compatible sealing resin and cure. Sealing does not restore severed reinforcement.

03

Label & Match Clips

Coordinate panel marks and suitable M-, C- or L-type fixing options, including the appropriate stainless grade.

Factory cutting can reduce site work.

Actual time savings depend on the layout and installation. Cutting still requires dust controls wherever it is performed. Stock, fabrication lead time and any 24–48-hour dispatch must be confirmed per order.

06 / Buyer FAQ

Frequently Asked Questions About FRP Grating Standard Sizes

What tolerances apply to standard molded grating panels?

The supplied catalog size table does not state manufacturing tolerances. Agree panel length, width, thickness and cutout tolerances on the approved order drawing. Do not assume a universal ±3–5mm panel tolerance or ±1.5mm depth tolerance.

Does molded FRP grating have a main load-bearing direction?

Square molded panels have reinforcement paths in two directions, but equal capacity must be checked for the exact product and supports. Rectangular mesh, edges and cutouts can affect behavior. Pultruded grating has a defined primary bearing-bar direction. Cutting can interrupt load paths.

How many standard panels fit in a 40ft high-cube container?

Prepare a packing plan using actual panel dimensions, thickness, gross weight, stacking protection, pallet sizes, door clearance and permitted payload. No fixed 450–500-panel count is assumed. For example, the page-4 38mm square panel weight is 19.5kg/m² before packaging.

Can I cut a panel on site using ordinary tools?

Follow product fabrication instructions using suitable tooling, dust extraction and protective equipment. Finish and seal exposed edges with compatible resin where specified. Verify supports and fixing positions after cutting.

Are 1220 × 3660mm and 1226 × 3666mm interchangeable?

They are different actual dimensions. The catalog lists configuration-specific footprints; confirm the selected tooling and finished panel drawing. Do not replace one size with the other or infer exact dimensions from a nominal 4 × 12ft description.

Does 19mm mini mesh mean a 19mm clear opening?

No. Mesh pitch is generally a center-to-center dimension. Clear aperture is reduced by the bar width and geometry. Obtain the actual opening drawing for small objects, wheels, heels or accessibility requirements.

07 / Standard panels & custom cuts

Need Standard Grating Sizes or Custom Cut-to-Size Panels?

Send your size list and project requirements to Hebei Leihong FRP Technology Co., Ltd. Request factory pricing, stock confirmation, samples and a drawing-based cutting proposal.

  • Actual panel size, thickness and mesh family
  • Resin, surface and color preference
  • Quantity, supports and loading conditions
  • Delivery destination and required date
Factory-direct inquiryCatalog size optionsCustom fabrication review

sales@leihongfiberglass.com
WhatsApp: +86 18831837530

Confirm availability, sample or freight charges, third-party inspection, response timing and dispatch with the quotation.

Prepare Your Size & Quantity Inquiry

Enter your contact details and include your size requirements in the message below.

Please enable JavaScript in your browser to complete this form.
Name

Email Drawings & Cutting List →

Open the Contact Form →