LEIHONG / INDUSTRIAL FLOORING
Anti Slip FRP Grating for Wet, Oily & Corrosive Workplaces
Specify non slip fiberglass grating with gritted or concave surfaces for industrial walkways, platforms and drainage areas. Coordinate traction, resin compatibility and structural loading in one factory-direct inquiry.
Hebei Leihong FRP Technology Co., Ltd. · Molded & pultruded grating · Project-specific documentation

01 / Product advantages
Industrial Slip Resistant Grating Built Around Your Working Conditions
A suitable surface is one part of walkway safety. Review the chemical exposure, footwear, drainage, loads and maintenance together.
Traction in working conditions
Gritted and concave textures provide different contact surfaces. Review wet or contaminated slip-test results for the proposed finish, footwear and route.
Resin matched to corrosion
Discuss orthophthalic, isophthalic and vinyl ester formulations for the actual chemical, concentration and temperature. FRP avoids steel rusting but still needs inspection.
Lightweight panel handling
Fiberglass construction can simplify handling compared with many steel alternatives. Verify stiffness, span and allowable deflection for the selected panel.
Electrical & fire requirements
Specify the required dielectric and fire tests. Nonconductive FRP is not automatically antistatic or approved for explosive atmospheres.
02 / Surface selection
Choose a Surface and Mesh for Your Application
Grit and concave profiles describe the walking surface. Micro mesh describes the opening pattern and can be combined with a specified surface finish.

Gritted FRP Grating
Discuss fine, medium or coarse grit, quartz or silicon carbide, and the bonding process. Evaluate a sample and relevant slip data for oil, detergent or other site contamination.
Discuss This Configuration
Concave Surface Fiberglass Grating
A molded meniscus profile provides bar edges for foot contact, with open mesh to drain liquids. Cleaning remains necessary; confirm suitability for the footwear and traffic.
Discuss This Configuration
Micro Mesh Anti Slip Grating
Smaller openings can reduce dropped-item risks and improve contact for some wheels. Confirm actual clear openings, surface texture, accessibility and wheel-load requirements.
Discuss This Configuration| Selection factor | Gritted | Concave | Micro mesh |
|---|---|---|---|
| Wear assessment | Inspect grit bond & wear | Inspect bar-edge wear | Depends on surface finish |
| Slip classification | Report required | Report required | Depends on surface finish |
| Barefoot use | Abrasive; separate review | Separate review | Opening and finish review |
| Cleaning | Clean grit texture | Clean edges and openings | Check debris retention |
Images are grating references, not certified texture specimens. Request the exact proposed mesh and finish for evaluation.
03 / Technical specification
Anti Slip FRP Grating Specifications, Sizes & Load Review
Select a nominal thickness to prepare your inquiry. Mesh, tooling, resin and surface availability must be confirmed for each combination.
| Nominal depth | Mesh pitch to discuss | Panel sizes to confirm | Structural data |
|---|---|---|---|
| 25 mm | 38 × 38 / 50 × 50 mm; 19 × 19 mm small-mesh options | 1220 × 3660 / 1000 × 4000 mm or drawing-based fabrication | Product-specific span, load and deflection table required |
| 30 mm | 38 × 38 / 50 × 50 mm; 19 × 19 mm small-mesh options | 1220 × 3660 / 1000 × 4000 mm or drawing-based fabrication | Product-specific span, load and deflection table required |
| 38 mm | 38 × 38 / 50 × 50 mm; 19 × 19 mm small-mesh options | 1220 × 3660 / 1000 × 4000 mm or drawing-based fabrication | Product-specific span, load and deflection table required |
| 50 mm | 38 × 38 / 50 × 50 mm; 19 × 19 mm small-mesh options | 1220 × 3660 / 1000 × 4000 mm or drawing-based fabrication | Product-specific span, load and deflection table required |
Inquiry dimensions only; this matrix does not establish that every thickness, mesh and panel size combination is available. Pitch is center-to-center spacing, not the clear opening. Pultruded panels require their own bar-direction specification.
Resin selection
Orthophthalic: discuss for suitable general service.
Isophthalic: discuss for selected industrial or water-treatment exposure.
Vinyl ester: evaluate for more demanding chemical service.
Chemical name, concentration, temperature and exposure duration determine compatibility. Resin family alone is insufficient.
Performance data to request
Slip classification and test conditions; Barcol hardness with test method; water absorption with method and conditioning; flexural properties and test orientation; fire and UV performance where specified.
R13, hardness ≥50 or absorption ≤0.2% are not assigned here without matching test evidence. A surface finish does not establish load capacity.
Load & Span Documentation
Send clear span, load type, contact area and deflection limit.
Chemical Compatibility Review
Specify the chemical, concentration and operating temperature.
38mm Grating Selection
Explore the 1 1/2 inch specification and engineering checklist.
View 38mm FRP Grating04 / Industrial applications
Match the Grating to the Environment
Discuss a configuration for your site rather than selecting from a universal load or slip rating.

Chemical & Petrochemical Platforms
Review chemical exposure, gritted finish, resin and operating temperature.
Discuss a Similar Configuration →
Wastewater Walkways
Review moisture, process gases, cleaning access and tank-edge supports.
Discuss a Similar Configuration →
Offshore & Marine Access
Review salt exposure, UV, uplift, fixings and site-specific approvals.
Discuss a Similar Configuration →
Food Processing & Washdown
Review fats, cleaning chemicals, hygiene and permitted washing pressure.
Discuss a Similar Configuration →
Wash Bays & Plating Trenches
Review detergents, drainage, electrolyte exposure and any wheel loads.
Discuss a Similar Configuration →
Boardwalks, Ramps & Stair Treads
Review slope, footwear, accessibility, edge contrast and tread fixings.
Discuss a Similar Configuration →Product and walkway images support application selection; these are not named or verified project case studies. Snow and ice require active control regardless of surface texture.

Grating product reference · Ask for relevant manufacturing and inspection documentation.
05 / Manufacturing & quality
Specify Durability from Material to Finished Panel
Work with Hebei Leihong FRP Technology Co., Ltd. to agree the construction, surface process and inspection scope before production.
- Material & formulation reviewConfirm resin, reinforcement and formulation requirements in the purchase specification.
- Surface application & curingConfirm the grit material, grading, application method and curing controls for the proposed panel.
- Fabrication & fixing planReview cutouts, edge sealing, bearing, panel identification and suitable stainless steel clips.
- Inspection & delivery agreementAgree dimensional checks, relevant performance evidence, packing and dispatch timing.
Current stock, sample timing, certification scope and any destructive or UV testing are confirmed per order. Grit surfaces remain subject to wear and inspection.
06 / Buyer FAQ
Anti Slip FRP Grating: Common Purchasing Questions
Will grit on anti slip FRP grating shed after several years?
Grit retention depends on the resin bond, application, curing and service conditions. Ask for the proposed process, samples and relevant wear evidence. No finish is permanently wear-proof; inspect heavily trafficked areas and repair or replace worn panels according to supplier guidance.
Which finish is best for very oily or icy outdoor conditions?
Coarse grit is an option to evaluate for oily work-boot routes, supported by testing under representative contamination. No grating finish guarantees grip through ice. Remove ice and snow, control contamination and drainage, and assess the route before use.
How do I clean non slip fiberglass grating?
Remove solid debris, brush the texture and use a cleaning agent compatible with the resin and contaminant. Rinse and restore drainage. Confirm water pressure, temperature and nozzle distance before pressure washing; excessive pressure or unsuitable chemicals can damage the surface.
Will site cutting damage the anti-slip surface or panel strength?
Cutting may expose fibers, disturb the finish near an edge and interrupt load paths. Follow fabrication instructions, use suitable dust controls and protective equipment, and seal cut edges with compatible resin. Confirm edge support and fixings; sealing does not restore severed structural reinforcement.
Can Leihong supply installation clips and a fixing arrangement?
Discuss M-, L- and C-type clips, including suitable 304 or 316 stainless steel options. Supply panel drawings, support details and environmental conditions so the clip geometry, grade and layout can be reviewed. Availability and quantities are confirmed in the quotation.
Can anti slip grating support heavy carts or forklifts?
A non-skid surface does not establish a wheel-load rating. Provide wheel loads, contact area, wheel spacing, travel direction, impact factors and span. Heavy-duty or forklift service needs a specifically engineered panel and support arrangement.
07 / Factory quotation
Configure Anti Slip FRP Grating for Your Next Project
Send your panel schedule, site photos or a dimensioned drawing to Hebei Leihong FRP Technology Co., Ltd. Discuss material selection, surface samples, load documentation and factory pricing.
- Quantity, panel dimensions and nominal thickness
- Surface, mesh, color and resin preference
- Clear span, traffic loads and chemical exposure
- Delivery country and required project date
sales@leihongfiberglass.com
WhatsApp: +86 18831837530
Confirm sample availability, any freight or sample charges, response timing and warranty terms with the quotation.
Request a Quote & Surface Samples
Include your company, quantity, thickness and application in the message field.
Email them with your panel dimensions and project requirements.
Email Drawings to Sales →